mirror of https://github.com/ecmwf/eccodes.git
Testing: Split long tests
This commit is contained in:
parent
d476cb7171
commit
02ffe19315
|
@ -126,6 +126,7 @@ if( HAVE_BUILD_TOOLS )
|
|||
bufr_ecc-359
|
||||
bufr_ecc-517
|
||||
bufr_rdbSubTypes
|
||||
bufr_operators
|
||||
grib_efas
|
||||
grib_sh_imag
|
||||
grib_spectral
|
||||
|
|
|
@ -1255,43 +1255,6 @@ diff ${f}.log.ref ${f}.log
|
|||
|
||||
rm -f ${f}.log ${f}.log.ref ${f}.out $fLog $fRules
|
||||
|
||||
#-----------------------------------------------------------
|
||||
# Test: change width using operator 201YYY
|
||||
#-----------------------------------------------------------
|
||||
HIGH_TEMPERATURE=10000
|
||||
cat > $fRules <<EOF
|
||||
set unpack=1;
|
||||
set airTemperature=$HIGH_TEMPERATURE;
|
||||
set pack=1;
|
||||
write;
|
||||
EOF
|
||||
f="bssh_176.bufr"
|
||||
|
||||
# This should fail. Out of Range
|
||||
set +e
|
||||
${tools_dir}/codes_bufr_filter -o ${f}.out $fRules $f
|
||||
status=$?
|
||||
set -e
|
||||
[ $status -ne 0 ]
|
||||
|
||||
# Now change the width of airTemperature to allow high value
|
||||
cat > $fRules <<EOF
|
||||
set unpack=1;
|
||||
set edition=4;
|
||||
set unexpandedDescriptors={301022,12023,201138,12101,201000,12023};
|
||||
set airTemperature=$HIGH_TEMPERATURE;
|
||||
set pack=1;
|
||||
print "airTemperature=[airTemperature], width=[airTemperature->width]";
|
||||
write;
|
||||
EOF
|
||||
${tools_dir}/codes_bufr_filter -o ${f}.out $fRules $f > ${f}.log
|
||||
|
||||
cat > ${f}.log.ref <<EOF
|
||||
airTemperature=$HIGH_TEMPERATURE, width=26
|
||||
EOF
|
||||
diff ${f}.log.ref ${f}.log
|
||||
|
||||
rm -f ${f}.log ${f}.log.ref ${f}.out $fLog $fRules
|
||||
#-----------------------------------------------------------
|
||||
# Test: DateTime
|
||||
#-----------------------------------------------------------
|
||||
|
@ -1353,51 +1316,6 @@ EOF
|
|||
diff ${f}.log.ref ${f}.log
|
||||
rm -f $f.log ${f}.log.ref
|
||||
|
||||
#-----------------------------------------------------------
|
||||
# Test: change reference val using operator 203YYY
|
||||
#-----------------------------------------------------------
|
||||
# Normally min. temperature = -99
|
||||
# max. nonlinearInverseSpectralWidth = 655.35
|
||||
# min. shortestOceanWavelengthOnSpectralResolution = 0
|
||||
f="$ECCODES_SAMPLES_PATH/BUFR4.tmpl"
|
||||
cat > $fRules <<EOF
|
||||
set masterTablesVersionNumber = 37;
|
||||
set inputOverriddenReferenceValues = { -100, 10000, -100 };
|
||||
set unexpandedDescriptors = {
|
||||
203015, 12023, 42008, 42007, 203255,
|
||||
12023, 42008, 42007,
|
||||
203000 };
|
||||
# Now setting out-of-range values will work
|
||||
set temperature = -100; # code 012023
|
||||
set nonlinearInverseSpectralWidth = 755; # code 042008
|
||||
set shortestOceanWavelengthOnSpectralResolution = -1; # code 042007
|
||||
set pack=1;
|
||||
write;
|
||||
EOF
|
||||
|
||||
${tools_dir}/codes_bufr_filter -o ${f}.out $fRules $f
|
||||
${tools_dir}/bufr_get -s unpack=1 \
|
||||
-p temperature,nonlinearInverseSpectralWidth,shortestOceanWavelengthOnSpectralResolution \
|
||||
$f.out > $f.log
|
||||
|
||||
cat > $f.log.ref <<EOF
|
||||
-100 755 -1
|
||||
EOF
|
||||
diff $f.log.ref $f.log
|
||||
|
||||
# Try with one element
|
||||
cat > $fRules <<EOF
|
||||
set masterTablesVersionNumber = 37;
|
||||
set inputOverriddenReferenceValues = { -150 };
|
||||
set unexpandedDescriptors = {
|
||||
203015, 12023, 203255, 12023, 203000 };
|
||||
set temperature = -101;
|
||||
set pack=1;
|
||||
write;
|
||||
EOF
|
||||
${tools_dir}/codes_bufr_filter -o $f.out $fRules $f
|
||||
res=`${tools_dir}/bufr_get -s unpack=1 -p temperature $f.out`
|
||||
[ "$res" = "-101" ]
|
||||
|
||||
|
||||
# Decode expandedDescriptors as array of string
|
||||
|
|
|
@ -0,0 +1,106 @@
|
|||
#!/bin/sh
|
||||
# (C) Copyright 2005- ECMWF.
|
||||
#
|
||||
# This software is licensed under the terms of the Apache Licence Version 2.0
|
||||
# which can be obtained at http://www.apache.org/licenses/LICENSE-2.0.
|
||||
#
|
||||
# In applying this licence, ECMWF does not waive the privileges and immunities granted to it by
|
||||
# virtue of its status as an intergovernmental organisation nor does it submit to any jurisdiction.
|
||||
#
|
||||
|
||||
. ./include.ctest.sh
|
||||
|
||||
# Define a common label for all the tmp files
|
||||
label="bufr_operators_test"
|
||||
|
||||
tempBufr=temp.$label.bufr
|
||||
tempFilt=temp.$label.filt
|
||||
tempLog=temp.$label.log
|
||||
tempRef=temp.$label.ref
|
||||
|
||||
#-----------------------------------------------------------
|
||||
# Test: change width using operator 201YYY
|
||||
#-----------------------------------------------------------
|
||||
HIGH_TEMPERATURE=10000
|
||||
cat > $tempFilt <<EOF
|
||||
set unpack=1;
|
||||
set airTemperature=$HIGH_TEMPERATURE;
|
||||
set pack=1;
|
||||
write;
|
||||
EOF
|
||||
input="${data_dir}/bufr/bssh_176.bufr"
|
||||
|
||||
# This should fail. Out of Range
|
||||
set +e
|
||||
${tools_dir}/codes_bufr_filter -o $tempBufr $tempFilt $input 2>/dev/null
|
||||
status=$?
|
||||
set -e
|
||||
[ $status -ne 0 ]
|
||||
|
||||
# Now change the width of airTemperature to allow high value
|
||||
cat > $tempFilt <<EOF
|
||||
set unpack=1;
|
||||
set edition=4;
|
||||
set unexpandedDescriptors={301022,12023,201138,12101,201000,12023};
|
||||
set airTemperature=$HIGH_TEMPERATURE;
|
||||
set pack=1;
|
||||
print "airTemperature=[airTemperature], width=[airTemperature->width]";
|
||||
write;
|
||||
EOF
|
||||
${tools_dir}/codes_bufr_filter -o $tempBufr $tempFilt $input > $tempLog
|
||||
|
||||
cat > $tempRef <<EOF
|
||||
airTemperature=$HIGH_TEMPERATURE, width=26
|
||||
EOF
|
||||
diff $tempRef $tempLog
|
||||
|
||||
|
||||
#-----------------------------------------------------------
|
||||
# Test: change reference val using operator 203YYY
|
||||
#-----------------------------------------------------------
|
||||
# Normally min. temperature = -99
|
||||
# max. nonlinearInverseSpectralWidth = 655.35
|
||||
# min. shortestOceanWavelengthOnSpectralResolution = 0
|
||||
f="$ECCODES_SAMPLES_PATH/BUFR4.tmpl"
|
||||
cat > $tempFilt <<EOF
|
||||
set masterTablesVersionNumber = 37;
|
||||
set inputOverriddenReferenceValues = { -100, 10000, -100 };
|
||||
set unexpandedDescriptors = {
|
||||
203015, 12023, 42008, 42007, 203255,
|
||||
12023, 42008, 42007,
|
||||
203000 };
|
||||
# Now setting out-of-range values will work
|
||||
set temperature = -100; # code 012023
|
||||
set nonlinearInverseSpectralWidth = 755; # code 042008
|
||||
set shortestOceanWavelengthOnSpectralResolution = -1; # code 042007
|
||||
set pack=1;
|
||||
write;
|
||||
EOF
|
||||
|
||||
${tools_dir}/codes_bufr_filter -o $tempBufr $tempFilt $f
|
||||
${tools_dir}/bufr_get -s unpack=1 \
|
||||
-p temperature,nonlinearInverseSpectralWidth,shortestOceanWavelengthOnSpectralResolution \
|
||||
$tempBufr > $tempLog
|
||||
|
||||
cat > $tempRef <<EOF
|
||||
-100 755 -1
|
||||
EOF
|
||||
diff $tempRef $tempLog
|
||||
|
||||
# Try with one element
|
||||
cat > $tempFilt <<EOF
|
||||
set masterTablesVersionNumber = 37;
|
||||
set inputOverriddenReferenceValues = { -150 };
|
||||
set unexpandedDescriptors = {
|
||||
203015, 12023, 203255, 12023, 203000 };
|
||||
set temperature = -101;
|
||||
set pack=1;
|
||||
write;
|
||||
EOF
|
||||
${tools_dir}/codes_bufr_filter -o $tempBufr $tempFilt $f
|
||||
res=`${tools_dir}/bufr_get -s unpack=1 -p temperature $tempBufr`
|
||||
[ "$res" = "-101" ]
|
||||
|
||||
|
||||
# Clean up
|
||||
rm -f $tempBufr $tempRef $tempLog $tempFilt
|
Loading…
Reference in New Issue