eccodes/tests/bufr_operators.sh

107 lines
3.1 KiB
Bash
Raw Permalink Normal View History

2023-07-21 15:56:57 +00:00
#!/bin/sh
# (C) Copyright 2005- ECMWF.
#
# This software is licensed under the terms of the Apache Licence Version 2.0
# which can be obtained at http://www.apache.org/licenses/LICENSE-2.0.
#
# In applying this licence, ECMWF does not waive the privileges and immunities granted to it by
# virtue of its status as an intergovernmental organisation nor does it submit to any jurisdiction.
#
. ./include.ctest.sh
# Define a common label for all the tmp files
label="bufr_operators_test"
tempBufr=temp.$label.bufr
tempFilt=temp.$label.filt
tempLog=temp.$label.log
tempRef=temp.$label.ref
#-----------------------------------------------------------
# Test: change width using operator 201YYY
#-----------------------------------------------------------
HIGH_TEMPERATURE=10000
cat > $tempFilt <<EOF
set unpack=1;
set airTemperature=$HIGH_TEMPERATURE;
set pack=1;
write;
EOF
input="${data_dir}/bufr/bssh_176.bufr"
# This should fail. Out of Range
set +e
${tools_dir}/codes_bufr_filter -o $tempBufr $tempFilt $input 2>/dev/null
status=$?
set -e
[ $status -ne 0 ]
# Now change the width of airTemperature to allow high value
cat > $tempFilt <<EOF
set unpack=1;
set edition=4;
set unexpandedDescriptors={301022,12023,201138,12101,201000,12023};
set airTemperature=$HIGH_TEMPERATURE;
set pack=1;
print "airTemperature=[airTemperature], width=[airTemperature->width]";
write;
EOF
${tools_dir}/codes_bufr_filter -o $tempBufr $tempFilt $input > $tempLog
cat > $tempRef <<EOF
airTemperature=$HIGH_TEMPERATURE, width=26
EOF
diff $tempRef $tempLog
#-----------------------------------------------------------
# Test: change reference val using operator 203YYY
#-----------------------------------------------------------
# Normally min. temperature = -99
# max. nonlinearInverseSpectralWidth = 655.35
# min. shortestOceanWavelengthOnSpectralResolution = 0
f="$ECCODES_SAMPLES_PATH/BUFR4.tmpl"
cat > $tempFilt <<EOF
set masterTablesVersionNumber = 37;
set inputOverriddenReferenceValues = { -100, 10000, -100 };
set unexpandedDescriptors = {
203015, 12023, 42008, 42007, 203255,
12023, 42008, 42007,
203000 };
# Now setting out-of-range values will work
set temperature = -100; # code 012023
set nonlinearInverseSpectralWidth = 755; # code 042008
set shortestOceanWavelengthOnSpectralResolution = -1; # code 042007
set pack=1;
write;
EOF
${tools_dir}/codes_bufr_filter -o $tempBufr $tempFilt $f
${tools_dir}/bufr_get -s unpack=1 \
-p temperature,nonlinearInverseSpectralWidth,shortestOceanWavelengthOnSpectralResolution \
$tempBufr > $tempLog
cat > $tempRef <<EOF
-100 755 -1
EOF
diff $tempRef $tempLog
# Try with one element
cat > $tempFilt <<EOF
set masterTablesVersionNumber = 37;
set inputOverriddenReferenceValues = { -150 };
set unexpandedDescriptors = {
203015, 12023, 203255, 12023, 203000 };
set temperature = -101;
set pack=1;
write;
EOF
${tools_dir}/codes_bufr_filter -o $tempBufr $tempFilt $f
res=`${tools_dir}/bufr_get -s unpack=1 -p temperature $tempBufr`
[ "$res" = "-101" ]
# Clean up
rm -f $tempBufr $tempRef $tempLog $tempFilt